07 3387 0400 [email protected] Region: Oceania Shop Now Account

Infant Hip Sonography Training Phantom

Kyoto Kagaku

Note: Pricing for this product is only available by quotation.

The best tool to teach Graf's method.

  1. World exclusive training model for hip sonography
  2. Full body manikin of 6-week-old infant
  3. Bilateral hip for examination
  4. Key landmarks that can be recognized under ultrasound include:
    • chondro-osseous junction(bony part of femoral neck), femoral head, synovial fold, joint capsule, labrum, hyaline cartilage preformed acetabular roof, body part of acetabular roof, body rim(check list 1), lowe limb of os ilium, correct plane, labrum(check list 2)
  5. Facilitate anatomical understanding

Hip sonography in newborns and infants can promote early detection and timely treatment of developmental dysplasia (DDH) and correct diagnosis saves patients from possible trouble and operation in the future. This is the world's first training phantom with ultrasound anatomy of a 6-week-old infant and it expands training opportunities for pediatricians, radiologists and orthopedists. Before working on real infants, trainees can repetitively practice on this phantom to become familiar with the examination procedures and key points. Using real ultrasound devices, trainees can learn key ultrasound landmarks to identify standard plane for Graf's classification. This is a foundation to acquire skills in handling and positioning of the baby as well as correct positioning of the transducer. The life-size full body manikin has soft limbs that allows for realistic training in supporting and changing the position of the infant while interacting with his/her guardian.

  • Setting and preparation for hip sonography
  • Changing the position of the infant
  • Communication and interaction with the infant's guardian
  • Correct positioning and use of transducer
  • Recognition of ultrasound landmarks for hip sonography
  • Visualization of standard, anterior and posterior planes
  • Interpretation and morphological classification of the sonogram

Set Includes:

  • 1 ultrasound infant phantom
  • instruction manual

Specifications:

  • phantom size: approx.W24xD13xH55cm/W9.4xD5.1xH21inch
  • weight: approx. 3.1kg/6.1lb

*Specifications are subject to change.

Additional Information


Notice: Undefined index: stores in /home/imagingsol/public_html/wp-content/themes/imaging-solutions/components/attachments.php on line 41

Notice: Undefined index: stores in /home/imagingsol/public_html/wp-content/themes/imaging-solutions/components/attachments.php on line 41

Related Information


Notice: Undefined index: stores in /home/imagingsol/public_html/wp-content/themes/imaging-solutions/components/attachments.php on line 92
US-13 Manual
Notice: Undefined index: stores in /home/imagingsol/public_html/wp-content/themes/imaging-solutions/components/attachments.php on line 92
US-13 Catalogue

Realizing Education That Inspires Through Manufacturing

Founded in 1891, Kyoto is the world’s only manufacturer of anatomical models, simulators, and imaging phantoms. Made in Kyoto, Japan and trusted in over 60 countries around the world. Passing on cultural heritage through technologies for restoring and replicating cultural assets.

More from Kyoto Kagaku

Notice: Function name was called incorrectly. Product properties should not be accessed directly. Backtrace: require('wp-blog-header.php'), require_once('wp-includes/template-loader.php'), include('/themes/imaging-solutions/index.php'), include('/themes/imaging-solutions/product.php'), include('/themes/imaging-solutions/components/contact-form.php'), WC_Abstract_Legacy_Product->__get, wc_doing_it_wrong Please see Debugging in WordPress for more information. (This message was added in version 3.0.) in /home/imagingsol/public_html/wp-includes/functions.php on line 6031

Notice: Function name was called incorrectly. Product properties should not be accessed directly. Backtrace: require('wp-blog-header.php'), require_once('wp-includes/template-loader.php'), include('/themes/imaging-solutions/index.php'), include('/themes/imaging-solutions/product.php'), include('/themes/imaging-solutions/components/contact-form.php'), WC_Abstract_Legacy_Product->__get, wc_doing_it_wrong Please see Debugging in WordPress for more information. (This message was added in version 3.0.) in /home/imagingsol/public_html/wp-includes/functions.php on line 6031
Infant Hip Sonography Training Phantom
https://imagingsol.com.au/product/infant-hip-sonography-training-phantom

Want to Know More?

[contact-form to=”[email protected]” subject=”Product Enquiry”][contact-field label=”Name” type=”name” required=”1″][contact-field label=”Product” type=”product”][contact-field label=”URL” type=”url”][contact-field label=”E-Mail” type=”email” required=”1″][contact-field label=”Phone Number” type=”text” required=”1″][contact-field label=”Company Name” type=”test” required=”0″][contact-field label=”Department” type=”test” required=”0″][contact-field label=”Company Address” type=”text” required=”0″][contact-field label=”Message” type=”textarea” required=”1″][/contact-form]