07 3387 0400 [email protected] Region: Oceania Shop Now Account

Angiographic Head Phantom

Radiology Support Devices Inc.

Evaluation Correlation of Image Quality with Actual Measurements of Resolution & Contrast

  • 3-dimensional high-contrast vascular pattern
  • Tissue equivalent materials
  • Step wedge and resolution test patterns
Note: Pricing for this product is only available by quotation.
SKU: N/A Category:
Clear

Available in opaque and transparent, full or half-head, RSD’s Angiographic Head Phantom bridges the gap between physical and anatomical information requirements. Molded in tissue equivalent material, an accurate male skull contains a 3-dimensional, 89+6 high-contrast vascular simulation to facilitate correlation of the radiologist’s subjective evaluation of angiographic image quality with actual measurements of resolution and contrast under the same exposure conditions.

The Angiographic Head Phantom provides a “dry run” to thoroughly assess angiographic equipment and ensure that is operating satisfactorily in all significant details before subjecting patients to radiological procedures. If the imaging system malfunctions, the phantom also plays a critically important role in isolating and verifying correction of problems. The Angiographic Head Phantom confines the variables to components and technique and has proven to be an invaluable service and teaching tool.

Applications

  • Teaching & training
  • Image quality
  • Dosimetry verification
  • Protocol verification

Modalities

  • CT
  • X-Ray
  • Fluoroscopy

The Angiographic Head Phantom is available as either a full or half head. The full head has the advantage of representing the full scatter properties and subject contrast of a human head. The half-head model is well suited to non-grid techniques. It has the advantages of lighter weight, lower cost and smaller size, easily fitting into a briefcase.

Each Angiographic Head Phantom contains a 5-step wedge. A 2-10 line pair/mm test pattern is optional. Other patterns or test objects and custom pathologies are available on special order.

The combination of the simulated vascular pattern, resolution chart, and step wedge enables the user to correlate physical parameters (such as resolution, contrast and speed) with the subjective evaluation of the skull markings and the vascular detail.

Unique RSD soft-tissue equivalent material is used for the skin tissue and neck and is adjusted to brain density in the cranium. This material closely duplicates brain tissues in radio-absorptive and scatter properties. The phantom is virtually shatterproof.

A high contrast 3-dimensional vascular pattern is placed in the median plane. The pattern closely resembles an internal carotid arteriogram in its early phase. The radio-density of the angiographic pattern has been adjusted to represent a 75% contrast-media. The phantom can be used omnidirectionally.

Model Numbers

  • RS-230             Full, Opaque, with step wedge
  • RS-230T           Full, Transparent, with step wedge
  • RS-235             Full, Opaque, with resolution test pattern (2-10 lp/mm) and step wedge
  • RS-235T           Full, Transparent, with resolution test pattern (2-10 lp/mm) and step wedge
  • RS-240             Half, Opaque, with step wedge
  • RS-240T           Half, Transparent, with step wedge
  • RS-245             Half, Opaque, with resolution test pattern (2-10 lp/mm) and step wedge
  • RS-245T           Half, Transparent, with resolution test pattern (2-10 lp/mm) and step wedge

Additional Information

Specifications

Opacity

Transparent, Opaque

Head

Full Head, Half Head

Extra

Resolution Test Pattern, Step Wedge

Founded by Samuel W. Alderson, the inventor of the crash test dummy and anthropomorphic test devices, RSD continues to be the industry leader with customizable, educational, and QC solutions for the global medical diagnostic and radiation therapy community.

More from Radiology Support Devices Inc.

Notice: Function name was called incorrectly. Product properties should not be accessed directly. Backtrace: require('wp-blog-header.php'), require_once('wp-includes/template-loader.php'), include('/themes/imaging-solutions/index.php'), include('/themes/imaging-solutions/product.php'), include('/themes/imaging-solutions/components/contact-form.php'), WC_Abstract_Legacy_Product->__get, wc_doing_it_wrong Please see Debugging in WordPress for more information. (This message was added in version 3.0.) in /home/imagingsol/public_html/wp-includes/functions.php on line 6031

Notice: Function name was called incorrectly. Product properties should not be accessed directly. Backtrace: require('wp-blog-header.php'), require_once('wp-includes/template-loader.php'), include('/themes/imaging-solutions/index.php'), include('/themes/imaging-solutions/product.php'), include('/themes/imaging-solutions/components/contact-form.php'), WC_Abstract_Legacy_Product->__get, wc_doing_it_wrong Please see Debugging in WordPress for more information. (This message was added in version 3.0.) in /home/imagingsol/public_html/wp-includes/functions.php on line 6031
Angiographic Head Phantom
https://imagingsol.com.au/product/alderson-angiographic-head-phantom

Want to Know More?

[contact-form to=”[email protected]” subject=”Product Enquiry”][contact-field label=”Name” type=”name” required=”1″][contact-field label=”Product” type=”product”][contact-field label=”URL” type=”url”][contact-field label=”E-Mail” type=”email” required=”1″][contact-field label=”Phone Number” type=”text” required=”1″][contact-field label=”Company Name” type=”test” required=”0″][contact-field label=”Department” type=”test” required=”0″][contact-field label=”Company Address” type=”text” required=”0″][contact-field label=”Message” type=”textarea” required=”1″][/contact-form]