07 3387 0400 [email protected] Region: Oceania Shop Now Account

Female Pelvic Ultrasound Phantom

Kyoto Kagaku

Note: Pricing for this product is only available by quotation.

Three interchangeable inserts to cover basic gyn and obs ultrasound.

Features

  1. Both transvaginal and transabdominal scanning are possible.
  2. Three types of interchangeable phantom inserts with different pathologies
  3. Realistic view of female external genital
  4. Excellent ultrasound image quality

The pelvic phantom is unique in that it allows for transabdominal and transvaginal scanning. Though transvaginal scanning is the gold standard for gyn and 1st trimester pregnancy, it is still important to recognise the anatomy from the transabdominal aspect, as patients may present with anatomy and /or pathology that is outside the transvaginal field of view. The transabdominal technique is still a valuable part of assessing the female pelvis. This phantom also provides imaging of normal and abnormal anatomy so that normal protocol can be practiced while still learning to recognise life threatening pathology, such as an ectopic pregnancy. Other pathology such as endometrial cancer and ovarian cysts can also be identified. In a learning environment, this phantom provides a balance of normal and abnormal that will assist in developing the critical thinking skills necessary to successfully evaluate the female pelvis.

Pathological unit

-endometrial cancer, uterine fibroid, dermoid cyst of ovary, bleeding at Douglas Cavum

Normal pregnancy unit (7 weeks)

Ectopic pregnancy unit

-ectopic pregnancy in a fallopian tube, bleeding at Douglas Cavum

Set Includes

US-10 Female Pelvic Ultrasound Phantom: 2 unit

  • 1 lower torso manikin
  • 1 ultrasound pathology unit for US-10
  • 1 ultrasound ectopic pregnancy unit for US-10
  • 1 storage case
  • Instruction manual

US-10A Female Pelvic Ultrasound Phantom: 3 unit

  • 1 lower torso manikin
  • 1 ultrasound pathology unit for US-10
  • 1 ultrasound first trimester pregnancy unit for US-10
  • 1 ultrasound ectopic pregnancy unit for US-10
  • 2 storage case
  • Instruction manual

US-10B Obstetrics Pelvic Ultrasound Phantom: 2 unit

  • 1 lower torso manikin
  • 1 ultrasound first trimester pregnancy unit for US-10
  • 1 ultrasound ectopic pregnancy unit for US-10
  • 1 storage case
  • Instruction manual

Specifications

  • phantom size: approx. W34xD33xH24cm/W13.4xD13xH9.5in
  • weight: approx. 6.5kg/14.5lb

*Specifications are subject to change.

Additional Information


Notice: Undefined index: stores in /home/imagingsol/public_html/wp-content/themes/imaging-solutions/components/attachments.php on line 41

Notice: Undefined index: stores in /home/imagingsol/public_html/wp-content/themes/imaging-solutions/components/attachments.php on line 41

Notice: Undefined index: stores in /home/imagingsol/public_html/wp-content/themes/imaging-solutions/components/attachments.php on line 41

Related Information


Notice: Undefined index: stores in /home/imagingsol/public_html/wp-content/themes/imaging-solutions/components/attachments.php on line 92
US10 Catalogue
Notice: Undefined index: stores in /home/imagingsol/public_html/wp-content/themes/imaging-solutions/components/attachments.php on line 92
US10 Manual
Notice: Undefined index: stores in /home/imagingsol/public_html/wp-content/themes/imaging-solutions/components/attachments.php on line 92
US10 Images

Realizing Education That Inspires Through Manufacturing

Founded in 1891, Kyoto is the world’s only manufacturer of anatomical models, simulators, and imaging phantoms. Made in Kyoto, Japan and trusted in over 60 countries around the world. Passing on cultural heritage through technologies for restoring and replicating cultural assets.

More from Kyoto Kagaku

Notice: Function name was called incorrectly. Product properties should not be accessed directly. Backtrace: require('wp-blog-header.php'), require_once('wp-includes/template-loader.php'), include('/themes/imaging-solutions/index.php'), include('/themes/imaging-solutions/product.php'), include('/themes/imaging-solutions/components/contact-form.php'), WC_Abstract_Legacy_Product->__get, wc_doing_it_wrong Please see Debugging in WordPress for more information. (This message was added in version 3.0.) in /home/imagingsol/public_html/wp-includes/functions.php on line 6031

Notice: Function name was called incorrectly. Product properties should not be accessed directly. Backtrace: require('wp-blog-header.php'), require_once('wp-includes/template-loader.php'), include('/themes/imaging-solutions/index.php'), include('/themes/imaging-solutions/product.php'), include('/themes/imaging-solutions/components/contact-form.php'), WC_Abstract_Legacy_Product->__get, wc_doing_it_wrong Please see Debugging in WordPress for more information. (This message was added in version 3.0.) in /home/imagingsol/public_html/wp-includes/functions.php on line 6031
Female Pelvic Ultrasound Phantom
https://imagingsol.com.au/product/female-pelvic-ultrasound-phantom

Want to Know More?

[contact-form to=”[email protected]” subject=”Product Enquiry”][contact-field label=”Name” type=”name” required=”1″][contact-field label=”Product” type=”product”][contact-field label=”URL” type=”url”][contact-field label=”E-Mail” type=”email” required=”1″][contact-field label=”Phone Number” type=”text” required=”1″][contact-field label=”Company Name” type=”test” required=”0″][contact-field label=”Department” type=”test” required=”0″][contact-field label=”Company Address” type=”text” required=”0″][contact-field label=”Message” type=”textarea” required=”1″][/contact-form]